SUPERLUMIS
RS‐232Control
5
Commands1‐9performdifferentactionsdependingontheprojectorstatus:
Status Command Action
Standby 0 switchestheunitonandselectsthelastinputmemorizedpriortoswitchoff
1‐5 switchtheunitonandselectcorrespondinginput
6‐9 switchtheunitonandselectthelastinputmemorizedpriortoswitchoff
On 0 displaystheInputSelectionwindowoftheOSD
1‐5 whenOSDisnotdisplayed,selectcorrespondinginputs
TheresponseoftheunittoaRemoteControlKeyCodedependsontheprojectorstatus:
Status Response Action
Standby 063A06................ Commandacknowledged(maybevalidorinvalid)
On 06 Validcommand(acknowledgedandvalidated)
15.. Invalidcommand(acknowledgedbutnotvalidated)
wherebytesmarkedwith..arenotrelevant.
2.2. OperationCommands
On
ThefollowingcommandsswitchtheunitOnandselectthedesiredinputatthesametime.SelectionoftheLastInput
(theonethatwasselectedatthemomentofthelastswitchoff)isalsopossible.
Action Command
TurnonandselectlastInput BEEF0206006BE6520100000000
TurnonandselectInput1 BEEF02060080E5490100000000
TurnonandselectInput2 BEEF020600B3E54A0100000000
TurnonandselectInput3 BEEF02060062E4
4B0100000000
TurnonandselectInput4 BEEF020600D5E54C0100000000
TurnonandselectInput5 BEEF02060004E44D0100000000
Ifthecommandisacknowledged,theresponseis:
063A06................
wherebytesmarkedwith..arenotrelevant.
Unfortunately, it is not possible todistinguish a valid command froman invalid one, as the response is the same in
bothcases.
Off
Action Command Response
Off BEEF02060051E4480100000000 OK 06
Error 15..
Brightness
Action Command Response
Increment BEEF1A0C005EA3000002000000000000000000 OK 20XX00
Decrement BEEF1A0C009BF2000003000000000000000000 Error 15..
Get BEEF1A0C005153000001000000000000000000
Intheresponse,XXisthehexrepresentationofthevalueofBrightness.
Example:ifthereturnedvalueisXX=3CthenBrightnessvalueis60.